GDL Vertical Inline Multistage Pump
Vertical Multistage Centrifugal Pump for High-Rise Water Supply & Pressure Boosting
GDL vertical inline multistage pump is a high-head centrifugal pump designed for high-rise water supply, pressure boosting, boiler systems, HVAC circulation and industrial water services. The vertical inline configuration allows direct pipeline installation while reducing floor space, and the multistage hydraulic design provides stable pressure for demanding water systems. GDL vertical inline multistage pumps are suitable for clean water and compatible liquids with properties similar to water. ZLZB® supplies GDL vertical multistage pumps with model selection based on required flow, head, liquid temperature, pipeline size and application requirements.
Flow Range:
2–160 m³/h
Head Range:
24–220 m
Power Range:
1.1–110 kW
Summary
GDL vertical inline multistage pump is designed for pipeline-mounted pressure boosting where installation space and piping layout are important. The suction and discharge connections are arranged inline, allowing the pump to be integrated directly into building and industrial water pipelines without a large floor footprint. Its multistage hydraulic structure provides the head required for high-rise water supply, booster systems, HVAC circulation, boiler water service and other pressurized clean-water applications. ZLZB® supplies GDL pumps for new installations and system upgrades, with model selection based on required flow, head, pipeline size, liquid temperature and operating conditions.
- Inline suction and discharge for direct pipeline installation
- Compact vertical layout reduces pump-room floor space
- Multistage hydraulics provide high head for pressurized systems
- Suitable for high-rise building and booster water systems
- Applicable to HVAC, boiler and industrial water pipelines
- Model selection based on flow, head and pipeline dimensions
Advantages
-
Inline Pipeline Installation
The GDL pump uses inline suction and discharge connections, allowing direct installation into building and industrial water pipelines with simplified piping layout. -
High-Rise Pressure Boosting
The multistage hydraulic design provides the head required for high-rise water supply, booster systems and other pressurized water applications. -
Space-Saving Vertical Layout
The vertical inline structure reduces floor-space requirements, making the GDL suitable for pump rooms, mechanical rooms and installations with limited space.
-
Stable Multistage Head Performance
Multiple hydraulic stages provide consistent head and pressure for water distribution, HVAC circulation, boiler water service and industrial pipeline systems. -
Easy Integration into Existing Systems
The inline configuration allows the pump to be incorporated into new piping systems or system upgrades without requiring a large separate pump foundation. -
Project-Based Pump Selection
ZLZB® supplies GDL vertical inline multistage pumps selected according to required flow, head, pipeline diameter, liquid temperature and operating conditions.
GDL Vertical Inline Multistage Pump Applications
High-Rise Building Water Supply
Water Pressure Boosting and Distribution Systems
Fire-Fighting & Jockey Systems
HVAC Chilled & Hot Water Circulation
Boiler Feed & Hot Water Systems
| Application Area | Typical Use Case |
|---|---|
| High-Rise Building Water Supply | GDL vertical inline multistage pump for high-rise residential, commercial and hotel water supply systems requiring stable high-head water delivery. |
| Pressure Boosting Systems | GDL vertical multistage pump for building pressure boosting, booster pump sets and pipeline systems requiring increased and stable water pressure. |
| Fire-Fighting & Jockey Systems | Vertical inline multistage pump for fire-fighting water supply, sprinkler pressure maintenance and jockey pump systems requiring compact pipeline installation. |
| HVAC Chilled & Hot Water Circulation | GDL vertical inline pump for HVAC chilled-water and hot-water circulation, air-conditioning systems and commercial building mechanical services. |
| Boiler Feed & Hot Water Systems | GDL multistage centrifugal pump for boiler water supply, hot-water circulation and heating systems requiring reliable pressure and continuous water delivery. |
| Industrial Process Water Supply | GDL vertical inline multistage pump for industrial process water supply, production equipment and high-pressure clean-water distribution systems. |
| Water Treatment & RO Feed | Vertical multistage centrifugal pump for water treatment equipment, RO feed systems, filtration units and clean-water applications requiring stable pressure and pipeline installation. |
Product Specifications
| Item | Specification |
|---|---|
| Pump Type | GDL Vertical Multistage Pipeline Centrifugal Pump |
| Flow Range | 2–160 m³/h |
| Head Range | 24–220 m |
| Power Range | 1.1–110 kW |
| Liquid Temperature | -15°C to +120°C |
| Wetted Material | Cast Iron / Stainless Steel (model dependent) |
| Connection | Flanged Connection |
| Frequency | 50 / 60 Hz |
| Motor Protection | IP55 |
| Standard Voltage | 3 × 380 V / 50 Hz (other voltages available on request) |
Performance Curves
Specification Data
| Model | Stages | Rated Flow (m³/h) | Flow (L/s) | Head (m) | Speed (r/min) | Power (kW) |
|---|
FAQ
-
How do I select the right GDL vertical inline multistage pump?
Select the pump according to required flow, head, pipeline diameter, liquid temperature, voltage and operating conditions. ZLZB® can recommend suitable GDL models based on your system and project requirements. -
What are GDL vertical inline multistage pumps mainly used for?
GDL pumps are commonly used for high-rise building water supply, pressure boosting, HVAC circulation, boiler water systems, industrial water supply and other pressurized clean-water applications. -
What is the advantage of the GDL vertical inline design?
The inline suction and discharge arrangement allows direct pipeline installation, reduces pump-room floor space and simplifies integration into new or existing water systems.
-
Can GDL pumps be used for high-rise building pressure boosting?
Yes. The multistage hydraulic design provides high head and stable pressure for high-rise residential, commercial and hotel water supply and booster systems. -
Can GDL pumps be used for fire-fighting, HVAC and boiler systems?
GDL pumps can be selected for pressure-maintenance, HVAC circulation and compatible boiler water applications when the pump configuration, materials and operating conditions meet the system requirements. -
What payment terms are available for GDL pump orders?
Payment terms can be discussed according to order quantity, project requirements and customer needs. Please contact ZLZB® for available payment options and quotation details.